A timber curtain wall seen from inside a lobby, with timber mullions framing floor-to-ceiling glass and a courtyard beyond.

H Window

How H Window Verified an EPD for a Configurable Curtain Wall

LEED v5 ready

A product-specific EPD for LEED v5 embodied carbon documentation.

One model, every wall

One LCA model covers every size, layout and material choice.

H Window used CarbonGraph to build one configurable LCA model and a verified EPD for its Timber Curtain Wall +. Now any architect can calculate the embodied carbon of the curtain wall they are specifying.

H Window used CarbonGraph to build one configurable LCA model and a verified EPD for its Timber Curtain Wall +. Now any architect can calculate the embodied carbon of the curtain wall they are specifying.

“Intuition needs to be backed up with real actionable data about the effective impacts of these materials through a verified EPD.”

– Brice Aarrestad, AIA, Director of Design, H Window

Company

H Window manufactures windows, doors, and timber curtain walls in Ashland, Wisconsin.

Challenge

Architects needed embodied carbon data for a high-performance product configured differently on nearly every project.

Solution

CarbonGraph built one configurable LCA model and took it through third-party verification with SmartEPD.

Results

Architects can now calculate the impact of the wall they are designing, backed by a verified EPD on EC3.

Bringing timber to the façade

H Window makes windows, doors, and timber curtain walls for architects and owners who care about design and energy performance. Its Timber Curtain Wall + is a fully engineered system that uses timber mullions as the structural framing for large glass walls, fabricated at the company’s Ashland, Wisconsin facility. It shows up in residential, commercial, and institutional projects, and demand is climbing. When Brice Aarrestad, H Window’s Director of Design, first spoke with CarbonGraph, he described new inquiries arriving every week.

Timber mullions framing the glass on an H Window Timber Curtain Wall +.

When every curtain wall is a custom curtain wall

H Window built its reputation on thermal performance. With a total unit U-factor of 0.26, the Timber Curtain Wall + keeps heat where it belongs, cutting the energy a building spends on heating and cooling for decades. That story has carried H Window a long way.

Now architects and owners are asking a second question: how much carbon is built into the wall before it ever reaches the site? They are asking because they have to. Public Buy Clean policies and owner procurement standards increasingly require EPDs, and under LEED v5, projects earn embodied carbon points by documenting enclosure products like curtain walls with product-specific EPDs. A product without one is harder to specify, no matter how good it is.

“The Mass Timber movement has been very effective in giving designers an intuitive understanding of the environmental benefits of using timber in construction.”

– Brice Aarrestad, AIA, Director of Design, H Window

For a timber system, that question should be an opportunity. But it is also where curtain walls get complicated. Every project has a different configuration: frame dimensions, mullion layout, mullion size, wood, glazing, and finish. A standard EPD describes one wall and says nothing about the one an architect is actually drawing. Even the wood varies from job to job.

“We really are all over the place. It’s not like 80% is one species.”

– Brice Aarrestad, AIA, Director of Design, H Window

Any manufacturer of a configurable product knows this bind. Brice needed embodied carbon data that matched each project, without commissioning a new study every time an architect changed the drawings.

One model built to flex

CarbonGraph’s answer was to stop treating the curtain wall as a single product and model it the way H Window sells it: as a system of choices. One LCA model of the Timber Curtain Wall + captures every component, from the timber mullions and aluminum profiles to the gaskets, hardware, and insulated glass. Then it turns the decisions that change from project to project into a control panel.

The Timber Curtain Wall + system: how it all goes together.

Each choice can be controlled by a set of input variables and switches. Sliders set the size and layout of the wall: how wide and tall it is, how many mullions it has, and how big they are. Switches pick the materials, like timber material, glazing type, or finish. Adjust a control and the results update to show the impacts for the project being specified. It has become a practical way to produce results for any project that specifies the Timber Curtain Wall +.

H Window’s impact calculator computes the specific environmental impacts of a project configuration.

The EPD’s verified cradle-to-gate result for the baseline wall is 88.5 kg CO₂e per m², with 49.9 kg from the frame and 38.6 kg from the glazing. That number is a starting point, not the only answer, because the EPD isn’t limited to a single configuration. It also reports a full set of impact indicators, including the biogenic carbon stored in the timber.

The real breakthrough was the proof that sits beside that number. CarbonGraph used the model to derive a scaling equation for the frame and took it through independent verification with SmartEPD alongside the results. Because every assumption lives in one model, each round of verifier feedback was applied once and carried through every configuration. The equation now ships with the EPD itself, so an architect can plug in the dimensions, mullion layout, and timber of their own wall and calculate its impact directly.

A verified EPD that flexes with the product

Now published through SmartEPD, the EPD is listed on EC3, the Building Transparency database that architects use to source lower-carbon materials.

  • Ready for specifiers: H Window can hand architects a third-party verified, product-specific EPD for whole-building LCAs and LEED documentation.

  • Any project, any configuration: Architects can calculate the impact of the wall they are designing, from walls 1 m to 12 m wide and 1 m to 6 m tall, without waiting on a new study.

  • Clear design levers: The model shows which choices matter most, so carbon can be weighed alongside thermal performance and design intent.

  • A model H Window owns: The model behind the EPD stays with H Window to run project scenarios and support future declarations.

That changes the sales conversation. When a project team asks about embodied carbon on a Timber Curtain Wall +, H Window no longer points to a generic industry figure or promises a study later. It hands over a verified EPD and a way to calculate the wall on the drawings, the same day.

“This EPD allows us to provide more clarity and confidence around our sustainability messaging and gives designers and owners tools they can use to achieve their project’s sustainability goals.”

– Brice Aarrestad, AIA, Director of Design, H Window

Turning the EPD into better sales conversations

H Window’s case for the Timber Curtain Wall + has always rested on design and performance: beautiful buildings that use less energy. The EPD adds proof for the part of the argument architects are now required to document, and it puts that proof where specifiers already look.

CarbonGraph also built H Window a sales tool on top of the verified EPD: an interactive impact calculator that shows how a wall’s configuration choices change its embodied carbon. Instead of sending an architect a document and waiting, H Window’s reps can walk through options with them in real time. Brice put it to the test at a recent industry conference, showing it to architects on an iPad. They were impressed by how it helps them make decisions early in a project, and many asked whether it would be available on H Window’s website.

“Equipping our product reps with special tools like the calculator ensures those conversations are happening and are productive.”

– Brice Aarrestad, AIA, Director of Design, H Window

Embodied carbon requirements will keep tightening, and manufacturers of configurable products will feel that pressure first. With one verified model that captures many configurations of the Timber Curtain Wall +, H Window can sell into LEED and Buy Clean projects with confidence.

View the H Window Timber Curtain Wall + EPD on SmartEPD or on EC3, and learn more about H Window at hwindow.com.

Ready to prove your sustainability advantage?

We'll build your first model with you.

Ready to prove your sustainability advantage?

We'll build your first model with you.

Ready to prove your sustainability advantage?

We'll build your first model with you.